Manufacturer of a wide range of products which include shimadzu uv vis spectrophotometer uv1900 i, rfm1000 cfr refractometer, uv vis spectrophotometer, rotary evaporator, lmms-5lc ceramic hotplate magnetic stirrer and lmms-300 hotplate magnetic stirrer.
Easy to Operate, Obtain Answers Easily and Rapidly High Performance to Meet Diverse Needs Validation functions enable checks in accordance with Pharmacopeia (JP, USP, and EP) to be performed easily In combination with LabSolutions™ DB/CS, comply with FDA 21 CFR Part 11 and PIC/S GMP guidelines
Microprocessor Control: The MS-300 hot plate magnetic stirrer is operated by a digital control CPU. The CPU regulates the heating up to 300 °C and 400 °C in the respective models & Model MS 200 is without Hot Plate.
Digital Speed Control: Stirring speed is also controlled by the CPU from the keypad while the stirring speed is indicated on the bar graph.
Programmable: Operator can setup the objective temperature, hold temperature, stirring time and speed.
Automatic Temperature Control:
Connect the temperature probe and place into glass container being stirred to measure and maintain the object temperature Accuracy is +1 °C.
pH Mode: Up to 5 points push-button calibration with auto-buffer recognition. Selectable pH buffer standards, (USA, DIN, NIST, User-defined) resolution (0.1, 0.01, 0.001 pH )temperature units ( Degree C or Degree F) Automatically calculates and displays electrode slope that helps you decide whether to replace pH electrode.Calibration due reminder prompts you to calibrate the meter regularly.
ORP Mode: Absolute or Relative mV measurements provides accurate ORP measured value 0.1 point offset calibration allows user adjusts displayed value to a known standard.
Conductivity/Tds/Salinity/Resistivity Mode: Up to 5-point push-button calibration allows user to uses customizedcalibration solutions. Default 10uS, 84uS, 1413uS, 12.88mS and 111.8mS)Adjustable TDS conversion factors, cell constants, temperature coefficients and normalization temperature. (20 C or 25 C)Allows user selects linear or pure water temperature compensation modes.In salinity measurement modes, selectable practical salinity (PSU) or seawater measurement standards.
Selectable either temperature units between degrees Celsius ( C) and degrees Fahrenheit ( F)
Automatic Temperature Compensation (ATC) ensures high accuracy of measurements
Automatic endpoint function freezes the stable measured values for easy reading and recording data.
Help message as a operational guide to helps you understand how to use meter.
Setup menu lets user customize the calibration points. stability conditions of measurement. temp. units and date/time to meet personal preference.
Reset function allows user to returns all setting to the factory default values.
Expanded memory stores and recalls upto 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into personal computer via USB communication interface
LMDO-50 use a polarographic electrode to measures dissolved oxygen in water, it can display the oxygen level as % saturation from 0 to 200% or concentration from 0 to 20ppm (mg/L).
One or Two points calibration (100% in air, 0% in zero oxygen solution)
Automatic temperature compensation for best accuracy under fluctuating temperatures
Automatically compensates salinity and barometric pressure after manual input for increased accuracy
Automatic message prompts help your easy to operate meter
Expanded memory stores and recalls up to 99 data sets
USB Communication interface can be sent data to computer